Please enter keywords to search

Global |EN

Choose your country & Language

Asia Pacific

Australia & New Zealand
India
Indonesia
Korea
Malaysia
Philippines
Singapore
Singapore (Sunlight)
Vietnam

Middle East & Africa

CHINT-EGEMAC
Saudi Arabia
South Africa
UAE
CHINT AJLAN

Europe

France
Italy
Spain
Turkey
Kazakhstan
Netherlands

North America

Mexico

Latin America

Brazil
Peru
Ecuador

Choose your country & Language

Australia & New Zealand
India
Indonesia
Korea
Malaysia
Philippines
Singapore
Singapore (Sunlight)
Vietnam
CHINT-EGEMAC
Saudi Arabia
South Africa
UAE
CHINT AJLAN
France
Italy
Spain
Turkey
Kazakhstan
Netherlands
Mexico
Brazil
Peru
Ecuador

Please enter keywords to search

Your search term contains restricted words. Please use different keywords.

Ultimate Guide of Cast Resin Dry-Type Transformer

AUG 30, 2022

Table of Contents

  1. What is a Cast Resin Dry Type Transformer?
  2. How Does a Cast Resin Dry Type Transformer Work?
  3. Which Are The Types of Dry Type Transformers?
  4. What Are The Advantages of Cast Resin Dry Type transformers?
  5. CHINT Dry Type Transformer
  6. Conclusion

Since the 1960s, dry-type transformers were the most common form of electric transformer produced. Their ease of use, effectiveness and inexpensive production costs account for their appeal.

As with any other electrical appliance, a dry-type transformer is built from a variety of parts to ensure effective operation. Although there are many different types of transformers, these dry-type transformers have become the most widely used because of their many advantages, including increased security.

If installed properly, these devices are incredibly dependable and can survive for decades with no maintenance. This guide on cast resin dry type transformers will go into great detail and cover dry type transformer upkeep and maintenance.

What is a Cast Resin Dry Type Transformer?

Electrical transformers known as cast resin dry type transformers use air as the insulator between their windings and core.

In a tank filled with air rather than a liquid, the windings and core of a dry transformer are sealed. Cast resin dry transformers aren’t as vulnerable to damage from electrocution, vibrations, or changes in temperature as oil-filled transformers. Additionally, they don’t need a lot of maintenance.

Dry transformers are frequently used in residential installations, where the wiring they serve may be out or exposed to harm despite the transformer itself being indoors. A dry transformer could be preferable to an oil-filled transformer if you reside in a region where flooding or lightning strikes are possible.

How Does a Cast Resin Dry Type Transformer Work?

The dry-type transformer insulates its windings and core without the need for fluids. Instead, a sealed cast epoxy resin that contains the windings and core is used.

In places with significant levels of moisture, cast resin dry-type transformers are used. It’s a result of the epoxy glue that surrounds its principal and secondary windings (non-hygroscopic). The winding can’t get wet because of the encapsulation.

Power ranges from 25 KVA up to 12,500 KVA, and the insulation class is F. (90oC Temp. Rise).

Low loss and low partial discharge. As a result, efficiency is excellent. It poses no risk of a fire hazard since non-flammable winding insulation is used. It can therefore be installed indoors.

Which Are The Types of Dry Type Transformers?

There are two main types of dry-type transformers;

Cast Resin

These transformers also referred to as CRTs, are enclosed in epoxy coating and are suitable for use in areas with a lot of moisture. This is done to stop moisture from getting within the windings, that would impair the functioning of the transformer.

These transformers are non-hygroscopic thanks to their cast resin encapsulation, which enables them to function dependably in humid environments.

Transformer Impregnated by Vacuum Pressure

High voltage is used when a vacuum pressure impregnated transformer functions, and its minimally flammable insulation is formed of foils and strips. The winding is formed of disks connected in series or parallel to accommodate larger voltages.

The insulation is moisture-resistant and impermeable to moisture since it is composed of class-H polyester resin.

What Are The Advantages of Cast Resin Dry Type transformers?

Self-extinguishing and Little Risk of Fire

These cast resin dry-type transformers have environmentally acceptable insulation. As a result, it winds comfortably, extinguishes on its own, is flame-resistant, and is of course simple to maintain.

You won’t need to spend money on a fire extinguisher if you have it. Plus, it doesn’t emit any harmful fumes, not even when arcing is present.

No Oil is Used.

The dry transformer doesn’t require any liquid to cool it, as was already mentioned. The only thing it needs to stay cool is air. Therefore, you won’t have to pay extra money for oil or other liquid, along with the associated maintenance fees. You may rest easy knowing that this transformer requires almost no maintenance.

Sustainable and Secure

You won’t have to worry about oil leaks because dry transformers don’t use oil or any other liquids. They also rarely explode since they self-extinguish. It comes with minimal electricity use, 90% reusable materials, and 20+ years of dependable service.

Low Installation and Load Cost

There are almost any restrictions for installing dry-type transformers because of their relatively safe nature, which results in reduced installation costs and minimal load losses. You won’t need to worry about additional environmental safeguards like groundwater protection.

Easily Maintained

We must stress this often. The dry-type transformers require very little upkeep. Like you hardly even need to keep up with them. You won’t ever have to bother with liquid testing. But a regular professional inspection is advised, and that shouldn’t be too challenging.

Dry-Type Transformer-Studio Image-3
Dry-Type Transformer-Studio Image-3
Dry-Type Transformer-Studio Image-3

CHINT Dry Type Transformer

Dry Epoxy Resin Cast

This CRT has a voltage range of 10 kV to 35 kV and many amazing qualities, including low-temperature rise, less noise output, strong moisture resistance, and highly secure and dependability.

For huge industrial buildings that require effective power distribution, this is a fantastic option.

Alloy Amorphous Core Dry

It also has good moisture and thermal performance, strong resistance to electrocution, low noise emission, and is compact and small in size. It is rated at 10kV up to 35kV volume and 10kV HV standard voltage.

This transformer works well in commercial and high-traffic locations like shopping malls, train stations, airports, and even facilities that process natural resources like oil platforms. This makes it ideal for places that are very flammable and explosive.

Conclusion

In many of the sectors that simplify our daily lives, dry-type transformers play a key role. But when a piece of equipment has such a large capacity, several easy and fundamental procedures must be taken to ensure that it is well-maintained and unlikely to cause accidents.

Various parts are included with dry transformers to assure their operation. They are excellent for low to medium range operating voltage since they are air-cooled and simple to maintain.

It is advisable to start early and invest in the correct dry type transformer, such as those offered by CHINT, if you want to make the most of your investment. The amorphous alloy core dry type transformer, as well as epoxy resin cast dry type transformer, are excellent choices, to maximize your investment.

The Latest
JULY 2, 2025 A Guide to the CHINT SMG Open Protocol Gateway: Building Flexible IoT Solutions

Discover how CHINT’s SMG-WSR/SMG-ESR Gateway and NB2 Circuit Breakers create smart, efficient, and remote-controlled electrical systems for various industries.

JULY 1, 2025 An Introduction to Power Circuit Breakers: How Do They Protect Your Industrial and Commercial Facilities?

Explore CHINT’s power circuit breaker solutions for high-performance electrical protection in industrial, commercial, and healthcare environments.

JULY 1, 2025 Understanding the VFD Working Principle in Industrial Automation

Learn the working principle of VFDs and discover how CHINT NVF7 boosts performance, energy savings, and equipment longevity in industrial automation.

JUNE 30, 2025 Gas Insulated Switchgear in Renewable Energy Integration

Learn how CHINT’s gas-insulated switchgear ensures stable, safe, and compact power distribution in renewable energy projects like wind and solar farms.

JUNE 30, 2025 Factors that Influence Commercial HVAC System Cost

Learn the major factors that impact commercial HVAC system pricing, from system types and tonnage to installation conditions and energy efficiency.

JUNE 27, 2025 Applications of Power Transformers in Solar Energy Systems

Discover how CHINT Global's power transformers enhance solar energy systems through efficient voltage regulation and grid integration for homes, businesses, and utility-scale projects.

JUNE 27, 2025 How to Wire a Low-Voltage Transformer

Discover essential safety precautions, wiring methods, and troubleshooting tips for low-voltage transformer setup. A complete guide for technicians and engineers.

JUNE 27, 2025 Water Pump Drives: PTO vs. Battery vs. Solar

Explore key benefits and drawbacks of PTO, battery-powered, and solar-powered water pump systems. Choose the right drive for your specific use case.

JUNE 26, 2025 How to Install a Changeover Switch for a Generator?

Discover how to install a manual changeover switch for your generator. Ensure safe and reliable power transfer with CHINT's expert tips and tools.

JUNE 25, 2025 RCBO Breakers Explained: How They Work, Wiring Diagrams, and Testing Tips

Discover how RCBO breakers protect against overloads and Earth leakages. Learn about wiring diagrams, differences from MCBs, and testing tips for safe operations.