Single Phase vs Three Phase Voltage Regulator

MARCH 26, 2025

Table of Contents

  1. Key Challenges of RMU in New Energy Applications
  2. CHINT Solution
  3. Conclusion

RMU, Ring Main Unit, is a medium voltage switchgear, consisting several electrical components, Load Break Switch, Circuit Breaker, Fuse, Surge Arrester, Instrument Transformer, Protection Relay, etc.

In the rapid growth of new energy applications, such as photovoltaic(PV), energy storage(BESS) and wind power, grid connection reliability and efficiency are important. RMU is the key equipment of this segment. Through the combination of multiple electrical switches, RMU realizes the operation of switching on, disconnecting and protecting of the electric energy.

Key Challenges of RMU in New Energy Applications

RMU is so important, so what may the problems customers face when choosing RMUs?

Application scenario 1:Prefabricated substation

1. Space Constraints

In PV, BESS and wind power applications, RMU is most used inside the prefabricated substation with a container or similar enclosure. Since transformers also need to be installed, the installation space left for RMU is quite limited. If the size of the RMU is too large, it is not easy to install.

2. Dust Effects

Some prefabricated substations may choose an open structure, with all equipment installed on the base. That solves the space limitation, but the installation environment of RMU will be changed from indoor to outdoor. Then it will be affected by sand and dust, which may cause RMU failure after a period of time.

3. Salt-spray Corrosion

Many of these new energy power plants will be installed on the coast. Equipment will suffer from salt spray corrosion for a long time. This may lead to gas leakage, cabinet rust, mechanism stuck and other problems in the RMU.

4. High Maintenance Cost

In new energy applications, the cost per kWh is an important factor affecting customer revenue. As a result, equipment requiring maintenance will increase operation and maintenance costs and reduce revenue. Especially many plants are located in remote areas, which further exacerbates this issue.

5. Installation Convenience and Operational Safety

Regardless of the installation method, the convenience of on-site installation and the safety protection of the operator are indispensable considerations.

Application scenario 2:Wind Tower RMU

In some of wind power plants, RMU is also installed in the prefabricated substation near the wind tower. But with the increase of wind turbine capacity, some manufacturers will choose to install RMU in the wind tower in order to reduce the cost per kWh.

In this case, RMU will be required to enter and exit through the tower door, and its maintenance conditions will be more harsh than prefabricated substations. This puts forward higher requirements on how to reduce RMU size, reduce maintenance cost and improve the stability of RMU products.

CHINT Solution

CHINT RMU NG7-40.5 is designed, manufactured and fully type tested according to IEC 62271-200. It's a product specifically designed and developed for new energy applications. With CHINT solution, you may get the following benefits and solve your concerns.

1. Can be installed within limited space

Extremely compact design makes it one of the smallest products at 36/40.5kV level.

2. Withstand high sandstorms and high corrosion harsh environments

Zn-Ni alloy mechanism, IP67 stainless-steel gas tank, IP4X cabinet and IP54 outdoor enclosure with advanced coating process. These features fulfill strong dust-proof and anti-corrosion capabilities.

3. Save maintenance time and costs

With a fully sealed and insulated structure, all switch and active parts are protected, which makes maintenance free.

4. Installation on site is convenient and flexible

All compartments are designed modular and individully. Gas work is fully done before delivery. Only building block installation is required on site.

5. Safe and reliable for operators and system

Comprehensive mechanical interlocking is designed for the products which can prevent accidental operation.

Conclusion

As new energy projects scale up globally, the need for reliable and adaptable grid connectivity solutions becomes critical. CHINT RMU not only solves the technical and environmental challenges, but also improves operational efficiency and profitability for customers. CHINT addresses customer challenges through innovation and supports the development of the new energy industry.

The Latest
APRIL 22, 2025 What is a New Energy Air Switch Disconnector: Facts You Need to Know

Discover how the new energy air switch disconnector (solar disconnector switch) plays a crucial role in ensuring safety and reliability in utility-scale solar and battery energy storage systems (BESS).

APRIL 15, 2025 What is a New Energy Air Switch Disconnector: Facts You Need to Know

Discover how the new energy air switch disconnector (solar disconnector switch) plays a crucial role in ensuring safety and reliability in utility-scale solar and battery energy storage systems (BESS).

APRIL 2, 2025 Experience Smooth Motor Starting with CHINT’s NJRP5-D Soft Starter

This article explains the differences between single phase voltage regulators and three phase voltage regulators.

MARCH 26, 2025 Single Phase vs Three Phase Voltage Regulator

This article explains the differences between single phase voltage regulators and three phase voltage regulators.

MARCH 21, 2025 MCCB vs ACB: What Are the Differences?

Circuit breakers differ depending on intended use and load capacities. This article explores the key differences between MCCB vs ACB.

MARCH 18, 2025 IEC vs. UL: Understanding Air Circuit Breaker Certification Standards

Compare IEC vs UL certification for air circuit breakers: regional standards, safety compliance, and CHINT's globally certified solutions for reliable electrical protection.

MARCH 17, 2025 IEC vs. UL: Understanding Air Circuit Breaker Certification Standards

NVF2L Compact Micro Drive is designed to meet the growing demand for efficient, space-saving solutions in various industrial applications. Explore CHINT's industrial drive technology solutions.

MARCH 5, 2025 The Basics of NVF2L Compact Micro Drive

NVF2L Compact Micro Drive is designed to meet the growing demand for efficient, space-saving solutions in various industrial applications. Explore CHINT's industrial drive technology solutions.

FEBRUARY 26, 2025 Key Differences Between Air Insulated Substations and Gas Insulated Substations

Common types of switchgear used in substations are AIS and GIS. This article will assess the primary difference between AIS and GIS substations for five critical aspects.

FEBRUARY 21, 2025 Key Differences Between Air Insulated Substations and Gas Insulated Substations

Common types of switchgear used in substations are AIS and GIS. This article will assess the primary difference between AIS and GIS substations for six critical aspects.